IMA

The Thermobile IMA is a high-efficiency mobile indirect-fired air heater. Equipped as standard with a maintenance-friendly Intercal front burner that can burn diesel, HVO and GTL. Suitable for heating larger spaces.

Need advice? Call +31 (0)7 65 87 34 50
 or send a message

  • Diesel
  • Petroleum/Kerosene
  • HVO
  • GTL
  • Optional: Propane Gas
  • Optional: Natural Gas

IMA

Compare Performances
IMA-61 AX
IMA-61 AX

65 kW

More information
IMA-61 RAD
IMA-61 RAD

65 kW

More information
IMA-111 AX
IMA-111 AX

110 kW

More information
IMA-111 RDD
IMA-111 RDD

110 kW

More information
IMA-111 RHP
IMA-111 RHP

110 kW

More information
IMA-150 RAD
IMA-150 RAD

150 kW

More information
IMA-150 RHP
IMA-150 RHP

150 kW

More information
IMA-200 RAD
IMA-200 RAD

200 kW

More information
IMA-200 RHP
IMA-200 RHP

200 kW

More information

Performance Chart

IMA-61 AX IMA-200 RHP IMA-150 RHP IMA-111 RDD IMA-111 AX IMA-150 RAD IMA-61 RAD IMA-200 RAD IMA-111 RHP
Max. Capacity (kW) 65 200 150 110 110 150 65 200 110
Airflow (m³/h) 4000 13000 11000 8000 5800 9000 4000 10000 10000
Measured Amperage 230V (A) 3.3 9 15 4.4 15 6.5 15 7.5
Power Connection (V/ph/Hz) 230/1/50 400/3/50 40/3/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50
Max. Fan Pressure (Pa) 130 500 500 300 130 300 250 300 500
Air Outlet Cone Ø (mm) 400 600 500 500 500 500 400 600 500
Chimney Connection Ø (mm) 180 200 200 200 200 200 180 200 200
Max. Fuel Consumption (l/h) 6.5 19.4 14.8 10.9 10.9 14.8 6.5 19.4 10.9
Thermostat Connection Yes Yes Yes Yes Yes Yes Yes Yes Yes
Dimensions LxWxH (cm) 162x71x128 271x91x152 246x84x151 223x78x134 179x78x134 246x84x151 199x71x128 271x91x152 223x78x134
Packaged Dimensions LxWxH (cm) 203x75x145 290x104x172 265x65x172 240x100x172 180x80x142 265x95x172 203x75x145 290x104x172
Weight (kg) 210 450 385 350 295 385 245 450 350
Packaged Weight (kg) 250 588 525 450 325 525 275 588
Measured Amperage (A) 10
Fuel Type Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane

Heat calculator

Calculate how much kW is needed for a specific room.
Characteristics
Automatic burner control with thermostat connection.
High-efficiency heat exchanger (approx. 92%).
Blow-out temperature with a delta ΔT of about 47°C.
Equipped with overheating protection and temperature limiter.
Fuel-efficient thanks to highly efficient heat exchanger and recirculation connection option.
Maintenance-friendly and easy to operate.
Easily movable.
Transport via wheels, forklift slots or lifting eyes.
Equipped with an Intercal industrial burner with flow control. Alternative burners available (e.g. Riello oil or gas burner).
Fleet Manager Essentials possible.
  • Applications
  • Documents
  • Heating of storage sheds, work areas, halls, sorting areas, construction sites, greenhouses and polytunnels.
  • Drying of new construction and renovation projects.
  • Drying and preservation of agricultural products.
40019003__10__MANUAL__IMA__LR40022010__06 IMA 61 111 150 200 RAD40022020__03 IMA 61 111 150 AXIAAL

  • Heating of storage sheds, work areas, halls, sorting areas, construction sites, greenhouses and polytunnels.
  • Drying of new construction and renovation projects.
  • Drying and preservation of agricultural products.

40019003__10__MANUAL__IMA__LR40022010__06 IMA 61 111 150 200 RAD40022020__03 IMA 61 111 150 AXIAAL

Frequently Asked Questions

The temperature of the intake air is reduced by about 12°C. It is therefore important to keep recirculating the air from the room to be cooled (the air is drawn in from the room and blown back into the room approximately 12°C cooler).

This depends on the floor area and volume, the insulation of the building and the application. A rule of thumb is 40 W per m³ for insulated buildings and 60 W per m³ for tents.

For all heaters with an oil-fired auxiliary burner, the burner can be replaced with a gas-fired auxiliary burner.

Read more

Get in touch!

Send an Email +31 (0)7 65 87 34 50


Download our catalogue

Download now
In-plant production
NL
Dutch quality since 1958
Global delivery
Customer-specific possible
Offers
  • Sectors
Sectors
  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control
Additionals
  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions
Thermobile Industries B.V.

Konijnenberg 80

4825 BD Breda

The Netherlands

Route via Google Maps

+31 (0)7 65 87 34 50


Contact

Linkedin

  • Sectors

  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control

  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions

Konijnenberg 80

4825 BD Breda

The Netherlands

Route via Google Maps

+31 (0)7 65 87 34 50


Contact

Linkedin

  • Terms and Conditions
  • Privacy Policy
Part of
×
close close

Login

Forgot your password?

No account yet? Apply here